So, youâre an electronics hobbyist and want a 1GHz* active probe, or a professional and tired of blowing your 2000$+ active probe in sketchy circuits when all you wanted to know are the whereabouts of some RF-signal?
Then stay with me!!
This Instructable will show you how to build a 1GHz* Fet-based Active Probe, the Fetprobe, for about 10$*, provided you have access to an electronics lab. It is based on an Elektor-magazine article (see the pdfâs addendum, section literature in my thesis) beside some other designs. However, as topic of my bachelor-thesis I wanted to find out how good these designs really are and how far one can push them.
If you go down this road, you need access to a lab that is equipped for some RF-fun, a cheap way for ordering RF-components and some rapid prototyping capabilities. Options some DIY-electronic-aficionados may not have. Although, my Bachelor-thesis comes with a lot of measured performance data, you will get pretty similar results if you stick to this tutorial.
In case you want to learn some more and donât mind a more scientific approach than have a look at my thesis included as PDF-file in last step.
Equipment needed to build this probe:
PCBs (512”m Rogers RO4003 w. 17”m copper dual-sided or similar) based on my gerber files
SMD soldering gear and tweezers!!
oscilloscope for debugging and testing
DC power supply
access to RF rated SMD component-kits (caps, resistors, inductors)
Components you need to get:
bf998 dual-gate Mosfet(s) SC-61B 4pin
RF-Rated 0603 caps around 1pF
10M 0603 resistor (bias)
spring-loaded tips often called pogo pins (RF_in and GND)
voltage regulator, i.e. LM317LCDR SOIC 8pin
SMA or BNC connector (RF_out)
add. Equipment needed to design & develop your own probe:
PCB mill, capable of SMD boards 125”m track-gap or similar etching process
VNA (Vector Network Analyzer)
swiss-army-knife RF software like AWR Microwave Office from National Instruments (layouting, spice-sim, RF-sim)
*: handles 1MHz-500MHz really well, usable up to 1GHz though (if you can accept a bit of dispersion and amplitude error, as shown in the S21-graphs in the last step
**: means you may need a membership in a laboratory, or acquire some peopleâs affection who do (i.e. via cold beverages). Also, the 20$ price tag suggests you only need to buy the special components, not the standard things which lie around in an RF-lab anyway.
Step 1: Motivation
Picture of Motivation
What is an active probe, anyway?
Assume you got a device you want to repair, and may encounter signals between 1MHz and 1GHz.. just stick in your beloved passive probe that came with the oscilloscope, no worries?
Not that great.
First and foremost, even if your probe is good for the RF-signalâs frequency you try to investigate, it still adds some capacitance to that trace you are probing. Some circuits may not like that and this is where the active probe comes to the rescue. Here, the amplifier in the probeâs head drives the cable and and other unavoidable capacitances so your circuit doesnât have to.
However there is more to it:
A passive probe, as shown in the diagram, uses a variable RC-element (labeled âcompâ) in its input path to compensate the transfer function (S21*) for lower frequency applications.
While that works for a certain freq. range, for higher frequencies (~200-800MHz+) the elements cannot be approximated as lumped elements anymore, and the compensation breaks down.
Also, a ground lead, especially a long and curled up one can prove dangerous, because it adds unwanted inductance, and may pick up some RF as well. Thatâs why you should always keep it as short and straight as possible, or remove it at all and add a more direct ground connection, like the RF grounding-spring to your passive probe if you are working on RF-circuits. My active probe has the same kind of spring-loaded tip for the GND connection as for the RF input.
So, what can this DIY active probe do?
be cheap & simple
relatively easy to build and maintain
probably suitable for low-level field or student use
How does it do that?
high input impedance S11*
stable transfer function
good pulse response, little nonlinear distortion (see THD in the pdf for more info)
*: The general term for resistance is impedance, and in the context of how much input impedance a measurement tool has, the input reflection coefficent S11 comes in handy (smaller = better).
S21 is the forward transmission coefficient, being a measure of the output signalâs power in relation to the input signalâs (here: being mostly stable over frequency = best).
Step 2: Circuit diagram
Picture of Circuit diagram
fet_filter_1.jpg
How to design such a device?
In essence, it has to be an impedance converter: High impedance (less power flowing away) for the DUT (device under test), controlled impedance (nice strong signal, low distortion) for the measurement instrument.
This can be based around an operational amplifier or a mosfet, but for me the fet-solution turned out to be better (see thesis-pdf in last step).
Above, you can see the schematic* of the Fetprobe, the fet-based Active Probe.
A very small input capacitor C_in in the input path guarantees that only veeery little current gets away from the DUT, and next to it a 10M bias-resistor ensures that the mosfet operates in its ideal DC-working-point (linear area of input-output relation. signal now is AC+DC). Now, the small signal itches the double-gated fet, which in turn creates a stronger signal. Followed up by the resistors R1 and R2 which determine the fetâs gain and help to better transmit waves over the coax (output impedance matching), especially on a 50Ohm system (typically used for RF-measurement equipment). Then, the DC-part of the signal (introduced for the happiness of the fet) gets chopped off by the capacitor C_out (not part of original signal).
At last, a filter dampens a resonance around 800MHz, with values around C1=C2=1.8pF, L=22nH.
It has to be noted that these values most likely have to be tuned separately for each Active Probe replica, as the resonance and the gain seem to vary due to manufacturing (your soldering, as well as the chip itself**).
**: Something like this could be automatically regulated by other fets/transistors, but the design goal âsimplicityâ forbids doing that (as well as the notion that every additional component, especially active ones, often introduce additional problems, and itâs very hard to get that all under control, pricey components inclusive. Thatâs part of why comparable professional tools may cost a hundredfold).
attached pdfâs: how the schematics look like in NIâs AWR
How to turn the schematic into hardware?
Well, itâs considered good practice to first build a prototype and demonstrate the concept (first picture).
Only then, as you know that your circuit actually works, the full-blown design (i.e. with its own voltage reg. instead of having a labPSU dedicated to it) makes sense to be implemented. Donât trust any spice-simulation over a real PCB too much, especially if you cascade many functional instances!
The other pictures show the 3D-View in NIâs AWR, as well as the real PCB.
Note that the RF-path is implemented as a 50Ohms line (Wave impedance, not resistance!) and kept clear of other traces for about one trace width or three times the substrate thickness, whatever results in the higher separation. The input-path kept as short as possible, the ground-plane is removed below it and the FET to get rid of parasitic capacities. Note that this first section leading up the FET is not impedance controlled, we want it to be as high impedance as possible to not disturb the circuit we are probing.
At the end of the day, you want to hold it in your hands or mount it to a stand, so two copper clad FR4-circuit boards (w. Kapton-tape finish) where attached as housing. They not only prevent your hands from touching the circuit, the standoffs provide some extra clearance. Therefore, prohibit interfering with the measurements since the input-pathâs 0.5pF and 10MOhm are in the same ballpark of what your fingers might do! Using FR4 circuit material as enclosure was just an easy way of utilizing the PCB mill to build the housing. If you donât have one, make something similar from sheet metal or even put it in a plastic case. However, be sure everything stays right clear of the business end to avoid unnecessary stray capacitance.
To supply power, the Fetprobe can use everything from 12 to 30 Volts (that is, its voltage regulator can handle). Note that the hardware implementation also features a few extra bypass capacitors (bias, supply of fet) and a few zero-Ohm-links, where protection diodes could go, depending how careful you are about the polarity when you are hooking it up. When choosing caps for the supply be sure to always team up different kinds in parallel. E.q. 2.3”F electrolytic and 100nF ceramic. This helps with overcoming the potentially poor RF performance of the electrolytic caps.
For More Details: DIY 1GHz Active Probe For Under 20$